Permit: T07PL00283

Parcel: 13613027F

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/07/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SHALL PROVIDE EACH PAN UNDER WATER HEATER FOR ELEVATED FLOOR WITH DRAIN.
2. VENT TO BE DOUBLE WALL LEAVING ENCLOSURE
MINIMUM 1' ABOVE ROOF WITH APPROVED VENT CAP
JOINTS OF VENT PIPING SHALL HAVE 3-GALV SCREWS AT EACH JOINT.