Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
3332 N ROMERO RD #048
Apply Date:
02/06/2007
Applicant:
ARTISTIC PLUMBING;*C,*P
Description:
GAS PRESSURE TEST (APA)
Contractors:
  • ARTISTIC PLUMBING;*C,*P

Outstanding Activity Conditions

Permit Number - T07PL00273
Permit Status: Expired
Permit Description: GAS PRESSURE TEST (APA)
Total Outstanding Activity Conditions - 1
Date Name
02/06/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07PL00273
Permite Description: GAS PRESSURE TEST (APA)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
02/14/2007 PLUMBING - GAS PRESSURE TEST N/A Partial Approval
02/15/2007 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
HENRY 275-2431
AGA VALVES REQUIRED AT APPLIANCE SHUT OFFS
WATER HEATER IS LEAKING, LEANING AND READY TO FALL THROUGH FLOOR. REPAIR FLOOR SET WH IN PAN.
T&P IS NOT PROPERLY TERMINATED
COMBUSTION AIR OPENINGS REQUIRED
SUPPORT SUSPENDED GAS PIPING FROM STRUCTURE NOT FROM BLOCKS SUPPORTING TRAILER. USE PIPE SUPPORTS TRAILER IS FOR SALE.