Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07MH00017
Permit Details
Apply Date:
01/30/2007
Applicant:
SILVERLAKE ESTATES
Description:
MH SET UP
Permit Reviews
Permit Number - T07MH00017
Permit Status: Expired
Permit Description: MH SET UP
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/30/2007 | MOBILE HOME | 01/30/2007 | COMPLETED |
01/30/2007 | MOBILE HOME | 02/16/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07MH00017
Permit Status: Expired
Permit Description: MH SET UP
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/30/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07MH00017
Permite Description: MH SET UP
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/02/2007 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. IMPROPER SPLICE AT RECEPTACLE WIRING ABOVE REFRIG. 2. TIMER SWITCH NOT GROUNDED 3. ROMEX ENTRY INTO SWITCH WRONG, NEEDS ROMEX CONNECTORS 4. GROUNDS AND NEUTRALS CANNOT BE CONNECTED 5. METAL COVER ABOVE SW BOX (CIRCUIT BREAKERS) NEEDS PLASTIC BUSHING 6. THE WIRING ON THIS MH HAS BEEN ALTERED 7. SINCE MH HAS BEEN RELOCATED IT REQUIRES A STATE OF ARIZONA MH INSPECTION IN ORDER TO CLEAR FOR POWER & GAS |