Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
8568 E LEE PL
Address NEW:
8568 E LEE PL
Apply Date:
10/22/2007
Applicant:
WALTER VIRGINIA
Description:
Replace 5 ton package gas/electric (roof mounted)
Contractors:
  • RITE WAY VENTILATING CO , *C

Outstanding Activity Conditions

Permit Number - T07ME00719
Permit Status: Closed
Permit Description: Replace 5 ton package gas/electric (roof mounted)
Total Outstanding Activity Conditions - 1
Date Name
10/22/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T07ME00719
Permite Description: Replace 5 ton package gas/electric (roof mounted)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/06/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 1/2" GAS LINE NOT ADEQUATE FOR 120,000 BTU
3/4" GAS LINE NOT ADEQUATE 70' FROM METER WITH
40,000 BTU WATER HEATER & 120,000 BTU FURNACE
PROVIDE 1" TO FEED FURNACE & WATER HEATER,
3/4 FOR FURNACE & 1/2 FOR WATER HEATER
2. PROVIDE PROPER DESCRIPTION OF WORK & ANY NECESSARY DRAWINGS APPROVED BY CITY OF TUCSON.

Completed Inspections

Permit Status: Closed
Permit Number: T07ME00719
Permit Description: Replace 5 ton package gas/electric (roof mounted)
Total Completed Inspections - 1
Date Description Inspector Results Comments
11/06/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW