Permit: T07ME00719
Permit Details
Apply Date:
10/22/2007
Applicant:
WALTER VIRGINIA
Description:
Replace 5 ton package gas/electric (roof mounted)
Contractors:
- RITE WAY VENTILATING CO , *C
Outstanding Activity Conditions
Permit Number - T07ME00719
Permit Status: Closed
Permit Description: Replace 5 ton package gas/electric (roof
mounted)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/22/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T07ME00719
Permite Description: Replace 5 ton package gas/electric (roof
mounted)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2007 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 1/2" GAS LINE NOT ADEQUATE FOR 120,000 BTU 3/4" GAS LINE NOT ADEQUATE 70' FROM METER WITH 40,000 BTU WATER HEATER & 120,000 BTU FURNACE PROVIDE 1" TO FEED FURNACE & WATER HEATER, 3/4 FOR FURNACE & 1/2 FOR WATER HEATER 2. PROVIDE PROPER DESCRIPTION OF WORK & ANY NECESSARY DRAWINGS APPROVED BY CITY OF TUCSON. |
Completed Inspections
Permit Status: Closed
Permit Number: T07ME00719
Permit Description: Replace 5 ton package gas/electric (roof
mounted)
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |