Permit: T07ME00635
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
3237 E PATRICIA ST
Address NEW:
3237 E PATRICIA ST
Apply Date:
09/04/2007
Applicant:
ABSOLUTE HEATING COOLING AND REFRIGERATION INC
Description:
HEAT PUMP:REPLACEMENT
Contractors:
- ABSOLUTE HEATING COOLING AND REFRIGERATION INC
Outstanding Activity Conditions
Permit Number - T07ME00635
Permit Status: Expired
Permit Description: HEAT PUMP:REPLACEMENT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/04/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07ME00635
Permite Description: HEAT PUMP:REPLACEMENT
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/06/2007 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* - DO NOT SCREW A MALE COPPER FITTING INTO A FEMALE PLASTIC - THE FITTING IS CRACKED AS A RESULT & LEAKING - CONDENSATE CANNOT TERMINATE INTO A SEWER VENT - DO NOT USE WHITE WIRE FOR THE GROUND OR THE HIGH VOLTAGE - PROPERLY IDENTIFY CONDUCTORS - PROVIDE A GFI SERVICE RECEPTACLE ON THE ROOF - NEED TO SEE THE CIRCUIT BREAKER FOR AC UNIT - MARK THE UNIT DATA PLATE WITH THE PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY |
Completed Inspections
Permit Status: Expired
Permit Number: T07ME00635
Permit Description: HEAT PUMP:REPLACEMENT
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/06/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |