Permit: T07ME00504
Permit Details
Apply Date:
07/11/2007
Applicant:
MORANDO MINI
Description:
VIRGIN INSTALL OF TRANE 3T SPLIT AC/GAS ( GONZALES 622.8898)
Contractors:
- AMERICAN HOME MAINTENANCE INC *C
Outstanding Activity Conditions
Permit Number - T07ME00504
Permit Status: Expired
Permit Description: VIRGIN INSTALL OF TRANE 3T SPLIT
AC/GAS ( GONZALES 622.8898)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/11/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07ME00504
Permite Description: VIRGIN INSTALL OF TRANE 3T SPLIT
AC/GAS ( GONZALES 622.8898)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2007 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN. - EVAP. COIL NOT A MATCH FOR FURNACE - RELOCATE STAT WIRE FROM TOUCHING FURNACE VENT - CONDENSATE PUMP HOSE REQUIRES HOSE CLAMPS - SECURE RECEPTACLE IN WALL - SECURE WATER LINE IN CLOSET - DISCONNECT ON ROOF OVERFUSED - EXTEND FURNACE VENT 3' ABOVE EVAP COOLER - USE WATER TITE CONNECTORS ON TOP OF CIRCUIT PANEL - MAINTAIN ADEQUATE CLEARANCE WHEN USING PVC NEAR THE FURNACE VENT CONNECTOR. |