Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
5372 E 3RD ST
Address NEW:
5372 E 3RD ST
Apply Date:
06/13/2007
Applicant:
MORANDO MINI
Description:
REPLACEMENT OF TRANE 4T SPLIT AC/GAS (HECKMAN 825.8938)
Contractors:
  • AMERICAN HOME MAINTENANCE INC *C

Outstanding Activity Conditions

Permit Number - T07ME00435
Permit Status: Expired
Permit Description: REPLACEMENT OF TRANE 4T SPLIT AC/GAS (HECKMAN 825.8938)
Total Outstanding Activity Conditions - 1
Date Name
06/13/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07ME00435
Permite Description: REPLACEMENT OF TRANE 4T SPLIT AC/GAS (HECKMAN 825.8938)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
06/19/2007 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
1. GAS FLEX CONNECTOR NOT ADEQUATE FOR 100,000 BTU FURNACE. PROVIDE A SEDIMENT TRAP.
2. PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN.
3. DO NOT USE WHITE WIRES FOR THE AC UNIT
4. CONDENSATE CANNOT TERMINATE INTO A SEWER VENT.
5. EXTEND THE FURNACE VENT MIN. 3' ABOVE COMBUSTION AIR INTAKE.

Documents

File Name Document Type  
None DOCUMENTS VIEW