Permit: T07ME00420
Permit Details
Apply Date:
06/08/2007
Applicant:
MORANDO MINI
Description:
REPLACEMENT OF TRANE 4T SPLIT AC/GAS (ARNDT 745.5462)
Contractors:
- AMERICAN HOME MAINTENANCE INC *C
Outstanding Activity Conditions
Permit Number - T07ME00420
Permit Status: Expired
Permit Description: REPLACEMENT OF TRANE 4T SPLIT
AC/GAS (ARNDT 745.5462)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/08/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07ME00420
Permite Description: REPLACEMENT OF TRANE 4T SPLIT
AC/GAS (ARNDT 745.5462)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/19/2007 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 3/8" I.D X 18" GAS FLEX NOT ADEQUATE FOR 96,000 BTU 2. PROVIDE SUPPORT UNDER PVC PIPE ON ROOF & PAINT ALL PVC W/LATEX PAINT. PROVIDE A ROOF JACK AT ROOF PENETRATION. 3. PROVIDE A GFI RECEPTACLE ON ROOF WITH A WATERPROOF COVER. 4. REPLACE THE WHITE WIRES USED FOR THE AC UNIT TAPING THEM BLACK WILL NOT BE ACCEPTED. PROVIDE A WATERPROOF FITTING WHERE ELEC. CONDUIT CONNECTS TO TOP OF PANEL. |