Description:
Replace 3 full split gas electric systems.
Contractors:
- RITE WAY VENTILATING CO , *C
Outstanding Activity Conditions
Permit Number - T07ME00366
Permit Status: Expired
Permit Description: Replace 3 full split gas electric systems.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/24/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07ME00366
Permite Description: Replace 3 full split gas electric systems.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2007 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* VENT PIPE FROM HORIZONTAL UNITS DOES NOT MATCH THE EXISTING VENT SYSTEM. DO NOT USE DIFFERENT MANUFACTURES VENT PIPE & DO NOT CUT THE ENDS TO MAKE THEM FIT. PERMANENTLY I.D CONDENSORS WITH A MATCHING NUMBER ON THE FAN COIL & AT THE CIRCUIT BREAKERS. THE CIRCUIT FOR THE 2 1/2 TON UNIT IS TOO LARGE. GATE CODE 0423 |
Completed Inspections
Permit Status: Expired
Permit Number: T07ME00366
Permit Description: Replace 3 full split gas electric systems.
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |