Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
05/21/2007
Applicant:
PERRY HEATING AND COOLING INC. *C
Description:
REPLACE: 3.5 TON GAS PACK (APA)
Contractors:
  • PERRY HEATING AND COOLING INC. *C

Outstanding Activity Conditions

Permit Number - T07ME00348
Permit Status: Expired
Permit Description: REPLACE: 3.5 TON GAS PACK (APA)
Total Outstanding Activity Conditions - 1
Date Name
05/21/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07ME00348
Permite Description: REPLACE: 3.5 TON GAS PACK (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/25/2007 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
1. GAS FLEX CONNECTOR HAS NO LISTING ATTACHED. TYPICALLY A 3/8" I.D X 18" GAS FLEX IS NOT ADEQUATE FOR 96,000 BTU. CLAMP THE GAS LINE TO THE BLOCKS ON THE ROOF.
2. PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE. YOU CAN CONVERT THE OLD EVAP. COOLER CIRCUIT IF NECESSARY

Documents

File Name Document Type  
None DOCUMENTS VIEW