Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
05/16/2007
Applicant:
MORANDO MINI
Description:
REPLACEMENT OF TRANE 3TON SPLIT AC/GAS ( GAY 791.3357)
Contractors:
  • AMERICAN HOME MAINTENANCE INC *C

Outstanding Activity Conditions

Permit Number - T07ME00341
Permit Status: Expired
Permit Description: REPLACEMENT OF TRANE 3TON SPLIT AC/GAS ( GAY 791.3357)
Total Outstanding Activity Conditions - 1
Date Name
05/16/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07ME00341
Permite Description: REPLACEMENT OF TRANE 3TON SPLIT AC/GAS ( GAY 791.3357)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/24/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. MAX. FUSE SIZE 30 AMPS, NOT 35
2. DO NOT USE WHITE CONDUCTOR A HOT POWER LEAD WIRE INTO UNIT.
3. PROTECT CONTROL WIRING AT CONDENSOR
4. THIS JOB NEEDS TO HAVE AN ELECTRICAL PERMIT
5. REFRIGERANT COPPER AT FURNACE SIDE WALL
SEPARATE/ISOLATE COPPER SUCTION LINE FROM STEEL FURNACE CASING. COMPLETE INSULATING SUCTION LINE.
6. LIMIT GAS FLEX TO 18" IN LENGTH SEAL CASING AROUND LINES AT PLENIUM.
7. WHERE IS CONDENSATE DRAIN TERMINATING?

Documents

File Name Document Type  
None DOCUMENTS VIEW