SINGLE FAMILY OTHER
Address NEW:
2111 E FLORENCE DR
Apply Date:
01/24/2007
Applicant:
PUEBLO HEATING & COOLING INC *C
Description:
REPLACE: 5 TON SPLIT SYSTEM (APA)
Contractors:
  • PUEBLO HEATING & COOLING INC *C

Outstanding Activity Conditions

Permit Number - T07ME00039
Permit Status: Expired
Permit Description: REPLACE: 5 TON SPLIT SYSTEM (APA)
Total Outstanding Activity Conditions - 1
Date Name
01/24/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07ME00039
Permite Description: REPLACE: 5 TON SPLIT SYSTEM (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
02/23/2007 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 3/8" I.D X 2' GAS FLEX NOT ADEQUATE FOR 100,000 BTU FURNACE.
2. USE THE PROPER REDUCER WHERE VENT CONNECTOR CONNECTS TO THE DOUBLE WALL VENT PIPE.
3. CONNECT THE OVERFLOW SENSOR ON CONDENSATE PUMP
4. DO NOT USE WHITE WIRE FOR POWER. TAPE ALL ENDS WITH BLACK TAPE.