Permit: T07EL02215
Permit Details
Apply Date:
12/21/2007
Applicant:
DENNIS BAXTER
Description:
RECONNECT:ELECTRIC:SFR R1: ADD OUTLETS TO PERMIT PER INSPECTOR
Permit Reviews
Permit Number - T07EL02215
Permit Status: Final
Permit Description: RECONNECT:ELECTRIC:SFR
R1: ADD OUTLETS TO PERMIT PER INSPECTOR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/26/2007 | ELECTRICAL | 12/26/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07EL02215
Permit Status: Final
Permit Description: RECONNECT:ELECTRIC:SFR
R1: ADD OUTLETS TO PERMIT PER INSPECTOR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/21/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07EL02215
Permit Description: RECONNECT:ELECTRIC:SFR
R1: ADD OUTLETS TO PERMIT PER INSPECTOR
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/24/2007 | ELECTRIC - RECONNECT | DSANTACR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. SMOKE DETECTORS REQUIRED IN HALLWAY & BEDROOMS 2. INSTALL GFI PROTECTED RECEPTS IN KITCHEN BY SINK AND BATHROOMS 3. EXPOSED ROMEX BELOW ROOF OVERHANG IN PORCH FOR DRYER, NEEDS TO BE IN WALL OR CONDUCTORS IN RACEWAY 4. SOMEONE ONLY UPGRADED THE BOTTOOM 1/2 OF THE SERVICE WITH 125 AMP PANEL, STILL HAS OLD 1" RISER WITH ROUND METER BASE - NOT GROUNDED PER CODE 5. INSTALL W/P BOX & COVER FOR COOLER RECEPT. ON ROOF |
| 01/03/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/03/2008 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/03/2008 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/04/2008 | PERMIT FINALED | JWEATHER | Approved | |
| 01/04/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. JIROUDEK |