Permit: T07EL02215

Parcel: 131130060


Addresses:

5941 E 33RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
01/03/2008 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
12/24/2007 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SMOKE DETECTORS REQUIRED IN HALLWAY & BEDROOMS
2. INSTALL GFI PROTECTED RECEPTS IN KITCHEN BY SINK AND BATHROOMS
3. EXPOSED ROMEX BELOW ROOF OVERHANG IN PORCH FOR DRYER, NEEDS TO BE IN WALL OR CONDUCTORS IN RACEWAY
4. SOMEONE ONLY UPGRADED THE BOTTOOM 1/2 OF THE SERVICE WITH 125 AMP PANEL, STILL HAS OLD 1" RISER WITH ROUND METER BASE - NOT GROUNDED PER CODE
5. INSTALL W/P BOX & COVER FOR COOLER RECEPT. ON ROOF