Permit: T07EL02161
Permit Details
Apply Date:
12/12/2007
Applicant:
RODRIGUEZ CELINA B
Description:
UPGRADE ELECTRICAL BOX
Permit Reviews
Permit Number - T07EL02161
Permit Status: Final
Permit Description: UPGRADE ELECTRICAL BOX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/12/2007 | ELECTRICAL | 12/12/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07EL02161
Permit Status: Final
Permit Description: UPGRADE ELECTRICAL BOX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/12/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07EL02161
Permit Description: UPGRADE ELECTRICAL BOX
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/24/2007 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. USE APPROVED RISER BRACE, HOMEMADE OUT OF SMASHED EMT NOT APPROVED. USE LISTED ASSEMBLY 2. USE PERMANENT ADDRESS LABEL FOR SERVICE ADDRESS, MUST BE SCREWED OR RIVETED TO ENCLOSURE 3. USE MIN. 1/4" BOLTS TO SUPPORT RISER CONDUIT TO WALL 4. SHEETMETAL OR WOOD SCREW NOT APPROVED TO GROUND J-BOX USE NUT & BOLT, SCRAP OFF ENAMEL 5. VERIFY WATER BOND |
| 01/28/2008 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | |
| 01/29/2008 | PERMIT FINALED | JWEATHER | Approved | |
| 01/29/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER D. SANTACRUZ |