Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
2201 S MARC DR
Address NEW:
2201 S MARC DR
Apply Date:
12/03/2007
Applicant:
ENGELHARDT JEFF & JANA CP/RS
Description:
UPGRADE:ELECTRIC: 60AMP TO 200AMP

Outstanding Activity Conditions

Permit Number - T07EL02103
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC: 60AMP TO 200AMP
Total Outstanding Activity Conditions - 1
Date Name
12/03/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T07EL02103
Permit Description: UPGRADE:ELECTRIC: 60AMP TO 200AMP
Total Completed Inspections - 6
Date Description Inspector Results Comments
12/21/2007 ELECTRIC - SERVICE UPGRADE RJIROUDE Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL GROUND RODS MIN 6' APART
2) INSTALL FILLER BLANKS IN DEAD FRONT
3) NEED DETAILED PANEL SCHEDULE
4) NEED PROTECTIVE BUSHING AROUND WIRES THROUGH BACK OF PANEL. SEAL OPENING WITH NON-COMBUSTIBLE MATERIAL
5) SUB PANEL NOT GROUNDED PROPERLY
6) INSTALL LISTED MAST BRACING CANNOT USE SMASHED EMT AND ? STRIP
7) ONE NEUTRAL PER TERMINAL NOT TO BE SHARED BY OTHER WIRES
12/21/2007 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/21/2007 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/21/2007 ELECTRIC - UNDERGROUND RJIROUDE Approved IVRS - Inspection :
See detailed listing on site.| 999*
02/11/2008 PERMIT FINALED JWEATHER Approved
02/11/2008 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED PER R. JIROUDEK

Documents

File Name Document Type  
None DOCUMENTS VIEW