Permit: T07EL02103
Permit Details
Apply Date:
12/03/2007
Applicant:
ENGELHARDT JEFF & JANA CP/RS
Description:
UPGRADE:ELECTRIC: 60AMP TO 200AMP
Outstanding Activity Conditions
Permit Number - T07EL02103
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC: 60AMP TO 200AMP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/03/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07EL02103
Permit Description: UPGRADE:ELECTRIC: 60AMP TO 200AMP
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2007 | ELECTRIC - SERVICE UPGRADE | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL GROUND RODS MIN 6' APART 2) INSTALL FILLER BLANKS IN DEAD FRONT 3) NEED DETAILED PANEL SCHEDULE 4) NEED PROTECTIVE BUSHING AROUND WIRES THROUGH BACK OF PANEL. SEAL OPENING WITH NON-COMBUSTIBLE MATERIAL 5) SUB PANEL NOT GROUNDED PROPERLY 6) INSTALL LISTED MAST BRACING CANNOT USE SMASHED EMT AND ? STRIP 7) ONE NEUTRAL PER TERMINAL NOT TO BE SHARED BY OTHER WIRES |
| 12/21/2007 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/21/2007 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/21/2007 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/11/2008 | PERMIT FINALED | JWEATHER | Approved | |
| 02/11/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. JIROUDEK |