Permit: T07EL02068
Permit Details
Apply Date:
11/26/2007
Applicant:
CONTRERAS MANUEL R & NATIVIDAD JT/RS
Description:
UPGRADE:ELECTRIC 100AMP TO 200 AMP
Permit Reviews
Permit Number - T07EL02068
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC 100AMP TO 200 AMP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/26/2007 | ELECTRICAL | 11/26/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07EL02068
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC 100AMP TO 200 AMP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/26/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07EL02068
Permite Description: UPGRADE:ELECTRIC 100AMP TO 200 AMP
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/04/2007 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED LISTED MAST BRACE - NOT EMT 2. GROUND RODS TO BE MINIMUM 6' APART 3. NEED PROPER TYPE BREAKERS FOR PANEL 4. WELDER BOX & RECEPTACLE TO BE RAIN TIGHT 5. IDENTIFY PANEL DIRECTORY 6. BOND GAS PIPE 7. PROPERLY CONNECT GROUNDS FOR TV & PHONE 8. MAX 15 AMP BREAKER FOR 14GA HOUSE WIRING (OR #12 COPPER) CORRECT AS NEEDED |
Completed Inspections
Permit Status: Expired
Permit Number: T07EL02068
Permit Description: UPGRADE:ELECTRIC 100AMP TO 200 AMP
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/29/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. JIROUDEK |