Permit: T07EL01904
Permit Details
Apply Date:
10/25/2007
Applicant:
AMERICAN QUALITY ELECTRIC INC
Description:
UPGRADE: 200 AMP (APA)
Contractors:
- AMERICAN QUALITY ELECTRIC INC
Outstanding Activity Conditions
Permit Number - T07EL01904
Permit Status: Final
Permit Description: UPGRADE: 200 AMP (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/25/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07EL01904
Permit Description: UPGRADE: 200 AMP (APA)
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2007 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL LISTED MAST BRACING CANNOT USE MINERALLAC STRAP & SMASHED EMT - NEC 110.3 & 230.28 2. REMOVE PAINT AT GROUND CLAMP CONNECTON ON WATER PIPE - NEC 250.12 3. PROVIDE DETAILED PANEL SCHEDULE WITH NO ABBREVIATIONS - NEC 408.4 4. CONNECT BONDING JUMPER FOR GAS PIPE TO GROUND/NEUTRAL BAR IN PANEL NOT METER SECTION. NEEDS TO BE ACCESSIBLE. NEC 250.104 5. HAS ENTIRE HOUSE BEEN REWIRED? PLEASE REVISE PERMIT FOR WORK DONE INSIDE HOUSE. |
| 04/21/2008 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | |
| 04/21/2008 | ELECTRIC - UNDERGROUND | WNORTH | Approved | |
| 04/22/2008 | PERMIT FINALED | JWEATHER | Approved | |
| 04/22/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER W. NORTH |