Permit: T07EL01790
Permit Details
Apply Date:
10/04/2007
Applicant:
K L S ELECTRIC INC ,
Description:
UPGRADE:ELECTRIC TO 200 AMP
Contractors:
- K L S ELECTRIC INC ,
Outstanding Activity Conditions
Permit Number - T07EL01790
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC TO 200 AMP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/04/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07EL01790
Permite Description: UPGRADE:ELECTRIC TO 200 AMP
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2007 | ELECTRIC - UNDERGROUND | N/A | Partial Approval | IVRS - Inspection :* |
| 11/02/2007 | ELECTRIC - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* 1) SEPERATE GROUNDS AND INSTALL AS PER MANUFACTURERS INSTRUCTIONS 2) SHEET METAL SCREWS NOT ALLOWED 250.8 3) ANTI-OXIDE COMPOUND NEEDED FOR ALL ALUMINUM CONDUCTORS 4) BOND SERVICE NIPPLE 25092 5) CIRCUIT DIRECTORY TO BE PER 408.4 |
| 11/02/2007 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection :* |
Completed Inspections
Permit Status: Expired
Permit Number: T07EL01790
Permit Description: UPGRADE:ELECTRIC TO 200 AMP
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. HOLLANDER |