Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07EL01525
Permit Details
Apply Date:
08/15/2007
Applicant:
N/A
Description:
INSTALL:ELECTRIC FOR WASHER/DRYER T07DV06998
Contractors:
- CONNECT ELECTRIC *C
Permit Reviews
Permit Number - T07EL01525
Permit Status: Expired
Permit Description: INSTALL:ELECTRIC FOR WASHER/DRYER T07DV06998
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/15/2007 | ELECTRICAL | 08/15/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07EL01525
Permit Status: Expired
Permit Description: INSTALL:ELECTRIC FOR WASHER/DRYER T07DV06998
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/15/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07EL01525
Permite Description: INSTALL:ELECTRIC FOR WASHER/DRYER T07DV06998
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2007 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. DO NOT HAVE PROPER WORKING CLEARANCE IN FRONT OF SERVICE EQUIPMENT - NEC 110.26 2. NEED TO INSTALL 4 WIRE CIRCUIT FOR ALL NEW DRYER CIRCUITS -- NEC 250.134 & 250. 138 3. INSTALL PROPER SIZE EQUIPMENT GROUNDING CONDUCTOR PER NEC 250.122 4. SECURE METAL FLEX PER NEC 348.30 |