Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
3731 N CHERRY AV
Address NEW:
3731 N CHERRY AV
Apply Date:
05/02/2007
Applicant:
AARMOR ELECTRIC
Description:
UPGRADE: 200 AMP
Contractors:
  • AARMOR ELECTRIC

Permit Reviews

Permit Number - T07EL00790
Permit Status: Expired
Permit Description: UPGRADE: 200 AMP
Start Date Submittal Complete Date Status  
05/02/2007 ELECTRICAL 05/02/2007 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T07EL00790
Permit Status: Expired
Permit Description: UPGRADE: 200 AMP
Total Outstanding Activity Conditions - 1
Date Name
05/02/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07EL00790
Permite Description: UPGRADE: 200 AMP
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/09/2007 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. USE A LISTED GUY KIT OR STIFF ARMS FOR MAST BRACE AND SECURE TO STRUCTURE (TRUSSES) EMT NOT ALLOWED
NEC 230.28
2. IDENTIFY SERVICE NEUTRAL OUT OF WEATHERHEAD NOT JUST AT END - NEC 200.6
3. MOVE SERVICE LUGS TO OVERHEAD POSITION AS INDICATED ON DIRECTION STICKER IN METER SECTION - NEC 110.3 B
4. EQUIPMENT GROUND TO J-BOX UNDERSIZED - NEC 250.122 C
5. PROVIDE SEPARATE, PROPERLY SIZED NEUTRAL FOR DRYER -- NEC 220
6. PROPERLY IDENTIFY NEUTRAL(S) IN J-BOX - NEC 200.6
7. NEC AC CKT TO DISCONNECT?

Documents

File Name Document Type  
None DOCUMENTS VIEW