Permit: T07EL00572
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
740 S AVENIDA LOS REYES
Address NEW:
740 S AVENIDA LOS REYES
Apply Date:
03/30/2007
Applicant:
VILLALBA LUCIA
Description:
panel upgrade to 200amps
Contractors:
- ENERGY SOURCE ELECTRIC INC *C
Outstanding Activity Conditions
Permit Number - T07EL00572
Permit Status: Expired
Permit Description: panel upgrade to 200amps
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/30/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07EL00572
Permite Description: panel upgrade to 200amps
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2007 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BOND OFFSET NIPPLE PER NEC 250.92 2. BOND SERVICE RISER PER NEC 250.92 3. SIZE BONDING JUMPERS PER NEC 250.102 4. BOND 1" EMT AT SERVICE PANEL PER NEC 250.98 REDUCING WASHERS USED. 5. SPLIT BOLT CONNECTURES HAVE TOO MANY WIRES TERMINATED - NO MORE THAN 2 WIRES 6. LABEL PANEL PER NEC 408.4 7. VERIFY WATER & GAS BONDING 8. IS OLD METER ENCLOSURE RATED FOR 200 AMPS 9. SERVICE ENERGIZED PRIOR TO APPROVALS. |