Permit: T07CM04725
Permit Details
Apply Date:
12/17/2007
Applicant:
ENRIQUE MORENO
Description:
NEW:SFR
Permit Reviews
Permit Number - T07CM04725
Permit Status: C of o
Permit Description: NEW:SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/05/2008 | RESUBMITTAL | 02/20/2008 | COMPLETED |
| 02/20/2008 | RESUBMITTAL | 03/26/2008 | COMPLETED |
| 12/17/2007 | PLANS OK TO SUBMIT - RES | 12/20/2007 | COMPLETED |
| 12/20/2007 | RESIDENTIAL BLDG/WWM | 01/23/2008 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T07CM04725
Permit Status: C of o
Permit Description: NEW:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/17/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM04725
Permit Description: NEW:SFR
Total Completed Inspections - 28
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2008 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | IVRS - Inspection :* 1) POST HOUSE NUMBER |
| 04/10/2008 | ELECTRIC - UNDERGROUND | EDURAZO | Approved | IVRS - Inspection :* |
| 04/10/2008 | ELECTRIC - UFER | EDURAZO | Approved | IVRS - Inspection :* |
| 04/10/2008 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
| 04/10/2008 | STEM WALL/RETAINING WALL | EDURAZO | Approved | IVRS - Inspection :* |
| 04/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
| 05/08/2008 | ROOF NAILING | CRUIZ | Approved | IVRS - Inspection :* |
| 05/08/2008 | EXT METAL CLIPS/EXT SHEATHING | CRUIZ | Approved | IVRS - Inspection :* |
| 06/23/2008 | PLUMBING - PRE SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
| 06/23/2008 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 07/08/2008 | ELECTRIC - TEMPORARY SERVICE | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/08/2008 | ELECTRIC - CABLE DROP | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/08/2008 | U VALUE FOR WINDOW | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/08/2008 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/09/2008 | TEP CLEARANCE - AM | BFLORES | Approved | ECO PER R.CAMACHO |
| 07/10/2008 | PLUMBING - GAS PRESSURE TEST | EDURAZO | Approved | IVRS - Inspection :* |
| 07/10/2008 | FRAMING | EDURAZO | Approved | IVRS - Inspection :* |
| 07/10/2008 | PLUMBING - INTERMEDIATE | EDURAZO | Approved | IVRS - Inspection :* |
| 07/10/2008 | ELECTRIC - INTERMEDIATE | EDURAZO | Approved | IVRS - Inspection :* |
| 07/22/2008 | PLUMBING - SEWER HCS CONNECT | WNORTH | Approved | IVRS - Inspection :* |
| 07/23/2008 | SHEET ROCK NAILING | WNORTH | Approved | IVRS - Inspection :* |
| 08/12/2008 | ASSURANCE | MCARREON | Approved | |
| 11/18/2008 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED BACKFLOW VALVES ON HOSE BIBBS 2) SEPERATE DIFFERENT SIZE WIRES DBL TAPED ON GROUND BAR 3) EXTERIOR SOUTH GFI HAS OPEN GROUND 4) REMOVE WIRE MESH SCREEN FROM DRYER VENT 5) MOVER OR CAP OFF CLOSET LIGHT IN N.W. BEDROOM 6) INSTALL STAIR RAILINGS 7) KITCHEN GFI'S MISWIRED |
| 11/18/2008 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/18/2008 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/18/2008 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/18/2008 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 04/27/2009 | PERMIT FINALED | JWEATHER | Approved |