Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address NEW:
6741 S MISSIONDALE RD
Apply Date:
11/27/2007
Applicant:
DAVID HALL
Description:
GAS AND ELECTRICAL RECONNECT

Outstanding Activity Conditions

Permit Number - T07CM04468
Permit Status: Final
Permit Description: GAS AND ELECTRICAL RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
11/27/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T07CM04468
Permit Description: GAS AND ELECTRICAL RECONNECT
Total Completed Inspections - 6
Date Description Inspector Results Comments
11/28/2007 PLUMBING - FINAL RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/28/2007 ELECTRIC - RECONNECT RCAMACHO Approved IVRS - Inspection :*
11/30/2007 TEP CLEARANCE - PM JWEATHER Approved RECN CLEARED PER R. CAMACHO
12/13/2007 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. SPA HTR IN AN ENCLOSED ROOM NO COMB/RELIEF AIR, HAS NO T&P ON HTR.
2. EXPOSED WIRING ON WALLS AT SPA HTR. ROOM
3. TWO BEDROOMS WITHOUT EMERGENCY EGRESS
4. RECEPTS IN SPA ROOM NOT GFCI PROTECTED
5. REMOVE TAPE FROM DBL - WALL TO SINGLE WALL FLUE
6. SWITCH BOX IN SPA ROOM HAS NO DEVICE OR COVER PLATE
7. FLEXIBLE GAS LINE RUN FOR RANGE THRU KIT CABINETS TO FURNACE, CONNECTED DIRECTLY TO RANGE
12/13/2007 PLUMBING - GAS RECONNECT RFREIDIN Approved IVRS - Inspection :
See detailed listing on site.| 999*
08/25/2008 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW