Permit: T07CM04468

Parcel: 138180740

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/22/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/05/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SCHNEIDER CONSTRUCTION TO OBTAIN PERMITS FOR STRUCTURES BUILT WITHOUT PERMITS
02/26/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REFER TO DNR WORK WITHOUT PERMITS-ADDITIONS, ELECTRICAL AND PLUMBING IN SHEDS
2) TERMINATE WATER HEATER TPR VALVE TO EXTERIOR-NO FLEX
3) PROVIDE SOMEONE ON SITE TO OPERATE BEDROOM SECURITY BARS TO VERIFY SAFE OPERATION
4 PROVIDE PROOF OF PERMITS FOR ALL ADDITIONS
2) FLEX LINE MAY NOT PENETRATE FURNACE
3) PROVIDE WEATHER TIGHT FITTINGS ALL EXTERIOR ELECTRICAL
4) PROVIDE APPROVED DETAILS FOR SPA HEATER EQUIPMENT OR MANUFACTURERS INSTALLATIONS OR APPROVED PLAN
5) PROVIDE APPROVED SITE PLAN FOR ALL STRUCTURES ON PROPERTY TO INCLUDE BATHROOM
6) PROVIDE ELECTRICAL PLAN TO SHOW ALL ELECTRICAL IN REAR YARD SHEDS
7) HAVE LICENSED ELECTRICAL CONTRACTOR CHECK ELECTRICAL TO CODE
02/13/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PHYSICAL PROTECTION REQUIRED ROMEX IN SPA HEATED ROOM UNDER 7'
2) UNABLE TO LOCATE PRESSURE RELIEF LINE TO EXTERIOR ON SPA HEATER
3) REMOVE TAPE AT FURNACE AND WATER HEATER JOINTS B-VENTS
4) EXTEND TPR VALVE WATER HEATER TO EXTERIOR
12/13/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SPA HTR IN AN ENCLOSED ROOM NO COMB/RELIEF AIR, HAS NO T&P ON HTR.
2. EXPOSED WIRING ON WALLS AT SPA HTR. ROOM
3. TWO BEDROOMS WITHOUT EMERGENCY EGRESS
4. RECEPTS IN SPA ROOM NOT GFCI PROTECTED
5. REMOVE TAPE FROM DBL - WALL TO SINGLE WALL FLUE
6. SWITCH BOX IN SPA ROOM HAS NO DEVICE OR COVER PLATE
7. FLEXIBLE GAS LINE RUN FOR RANGE THRU KIT CABINETS TO FURNACE, CONNECTED DIRECTLY TO RANGE
11/28/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LABEL ALL CIRCUITS ALL PANELS
2) PROVIDE HIGH/LOW COMBUSTION RELIEF VENTS WATER HEATER ROOM 100 CU INCHES EACH
3) PROVIDE WORKING SMOKE DETECTORS HALLWAYS AND BEDROOMS
4) EXPOSED WIRING IN BOX REAR ADDITION