Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
11/16/2007
Applicant:
RICHMOND AMERICAN HOMES *C
Description:
NEW SFR TD# 16-60-09 T06-M0030
Contractors:
  • RICHMOND AMERICAN HOMES *C

Permit Reviews

Permit Number - T07CM04403
Permit Status: C of o
Permit Description: NEW SFR TD# 16-60-09 T06-M0030
Start Date Submittal Complete Date Status  
11/16/2007 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 11/19/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM04403
Permit Status: C of o
Permit Description: NEW SFR TD# 16-60-09 T06-M0030
Total Outstanding Activity Conditions - 1
Date Name
11/16/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM04403
Permit Description: NEW SFR TD# 16-60-09 T06-M0030
Total Completed Inspections - 24
Date Description Inspector Results Comments
11/30/2007 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
11/30/2007 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
12/27/2007 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved
12/27/2007 ROOF NAILING RFREIDIN Approved IVRS - Inspection :*
1) 3 X MEMBERS REQUIRED AT SW9 SHEAR VERT JOINTS
2) SHIM 3 PT BEAM BEARING AT GARAGE
3) EPOXY BOLTS EXPOSED AT REAR CONCRETE
4) MISSED NAILING ON GARAGE ROOF
5) INSTALL WIND BRACE 2ND FLOOR NORTH EAST CORNER
6) H.D. 1ST FLOOR SOUTH WEST CORNER IS ON WRONG WALL
7) NAIL ALL OSB SHEAR TO STUDS ATTACHED TO H.D.'S
8) NAIL ALL 2ND FLOOR PLATES 12" ON CENTER WITH 16D'S
9) SEE DETAILS 15/S1.1 AND 11/S1.1 FOR SHEAR TRANSFER AT EACH SIDE OF GARAGE OPENING #9 SHEAR WALL ADD STUDS PER DETAIL 15, RUN WALL SHEATHING UP TO ROOF PER DETAIL 11
01/10/2008 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
01/10/2008 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
01/10/2008 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
01/10/2008 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
01/10/2008 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
01/10/2008 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
01/14/2008 FRAMING WNORTH Approved IVRS - Inspection :*
02/05/2008 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
02/14/2008 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
02/14/2008 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
02/15/2008 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
03/07/2008 ASSURANCE MCARREON Approved
03/25/2008 ELECTRIC - UFER WNORTH Approved
03/25/2008 BUILDING PRE-SLAB WNORTH Approved
03/25/2008 EXCAVATION/LAYOUT REBAR & ZON WNORTH Approved
03/25/2008 MECHANICAL - FINAL WNORTH Approved IVRS - Inspection :*
03/25/2008 PLUMBING - FINAL WNORTH Approved IVRS - Inspection :*
03/25/2008 ELECTRIC - FINAL WNORTH Approved IVRS - Inspection :*
03/25/2008 BUILDING - FINAL WNORTH Approved IVRS - Inspection :*
03/26/2008 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
C OF O_03-26-2008.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
SITE PLAN_11-19-2007.TIF CONSTRPLANS VIEW