Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM04403
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
9084 S WHISPERING PINE DR
Address NEW:
9084 S WHISPERING PINE DR
Apply Date:
11/16/2007
Applicant:
RICHMOND AMERICAN HOMES *C
Description:
NEW SFR TD# 16-60-09 T06-M0030
Contractors:
- RICHMOND AMERICAN HOMES *C
Permit Reviews
Permit Number - T07CM04403
Permit Status: C of o
Permit Description: NEW SFR TD# 16-60-09 T06-M0030
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/16/2007 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/19/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM04403
Permit Status: C of o
Permit Description: NEW SFR TD# 16-60-09 T06-M0030
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/16/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM04403
Permit Description: NEW SFR TD# 16-60-09 T06-M0030
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/30/2007 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection :* |
| 11/30/2007 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :* |
| 12/27/2007 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | |
| 12/27/2007 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection :* 1) 3 X MEMBERS REQUIRED AT SW9 SHEAR VERT JOINTS 2) SHIM 3 PT BEAM BEARING AT GARAGE 3) EPOXY BOLTS EXPOSED AT REAR CONCRETE 4) MISSED NAILING ON GARAGE ROOF 5) INSTALL WIND BRACE 2ND FLOOR NORTH EAST CORNER 6) H.D. 1ST FLOOR SOUTH WEST CORNER IS ON WRONG WALL 7) NAIL ALL OSB SHEAR TO STUDS ATTACHED TO H.D.'S 8) NAIL ALL 2ND FLOOR PLATES 12" ON CENTER WITH 16D'S 9) SEE DETAILS 15/S1.1 AND 11/S1.1 FOR SHEAR TRANSFER AT EACH SIDE OF GARAGE OPENING #9 SHEAR WALL ADD STUDS PER DETAIL 15, RUN WALL SHEATHING UP TO ROOF PER DETAIL 11 |
| 01/10/2008 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | U VALUE FOR WINDOW | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/10/2008 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :* |
| 01/14/2008 | FRAMING | WNORTH | Approved | IVRS - Inspection :* |
| 02/05/2008 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/14/2008 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/14/2008 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection :* |
| 02/15/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER R. FREIDINGER |
| 03/07/2008 | ASSURANCE | MCARREON | Approved | |
| 03/25/2008 | ELECTRIC - UFER | WNORTH | Approved | |
| 03/25/2008 | BUILDING PRE-SLAB | WNORTH | Approved | |
| 03/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | WNORTH | Approved | |
| 03/25/2008 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 03/25/2008 | PLUMBING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 03/25/2008 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 03/25/2008 | BUILDING - FINAL | WNORTH | Approved | IVRS - Inspection :* |
| 03/26/2008 | PERMIT FINALED | JWEATHER | Approved |