Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T07CM04403
Inspection Description - ROOF NAILING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/03/2008 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 12/27/2007 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) 3 X MEMBERS REQUIRED AT SW9 SHEAR VERT JOINTS 2) SHIM 3 PT BEAM BEARING AT GARAGE 3) EPOXY BOLTS EXPOSED AT REAR CONCRETE 4) MISSED NAILING ON GARAGE ROOF 5) INSTALL WIND BRACE 2ND FLOOR NORTH EAST CORNER 6) H.D. 1ST FLOOR SOUTH WEST CORNER IS ON WRONG WALL 7) NAIL ALL OSB SHEAR TO STUDS ATTACHED TO H.D.'S 8) NAIL ALL 2ND FLOOR PLATES 12" ON CENTER WITH 16D'S 9) SEE DETAILS 15/S1.1 AND 11/S1.1 FOR SHEAR TRANSFER AT EACH SIDE OF GARAGE OPENING #9 SHEAR WALL ADD STUDS PER DETAIL 15, RUN WALL SHEATHING UP TO ROOF PER DETAIL 11 |