Permit: T07CM04403

Parcel: 141314980

Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T07CM04403

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
01/03/2008 ROOF NAILING Approved IVRS - Inspection :*
12/27/2007 ROOF NAILING Partial Approval IVRS - Inspection :*
1) 3 X MEMBERS REQUIRED AT SW9 SHEAR VERT JOINTS
2) SHIM 3 PT BEAM BEARING AT GARAGE
3) EPOXY BOLTS EXPOSED AT REAR CONCRETE
4) MISSED NAILING ON GARAGE ROOF
5) INSTALL WIND BRACE 2ND FLOOR NORTH EAST CORNER
6) H.D. 1ST FLOOR SOUTH WEST CORNER IS ON WRONG WALL
7) NAIL ALL OSB SHEAR TO STUDS ATTACHED TO H.D.'S
8) NAIL ALL 2ND FLOOR PLATES 12" ON CENTER WITH 16D'S
9) SEE DETAILS 15/S1.1 AND 11/S1.1 FOR SHEAR TRANSFER AT EACH SIDE OF GARAGE OPENING #9 SHEAR WALL ADD STUDS PER DETAIL 15, RUN WALL SHEATHING UP TO ROOF PER DETAIL 11