Permit: T07CM04350
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
5151 E BROADWAY BL #1750
Address NEW:
5151 E BROADWAY BL #1750
Apply Date:
11/13/2007
Applicant:
INTERTECH
Description:
TI: LAW OFFICE
Contractors:
- CALDWELL CONSTRUCTION L L C *C*
Permit Reviews
Permit Number - T07CM04350
Permit Status: C of o
Permit Description: TI: LAW OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/13/2007 | COMMERCIAL TI | 12/13/2007 | COMPLETED |
| 12/13/2007 | REVISION - - 1ST | 12/13/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM04350
Permit Status: C of o
Permit Description: TI: LAW OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/13/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM04350
Permit Description: TI: LAW OFFICE
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/28/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* PLEASE ENSURE THAT NORTH WALL OF ROOM #116 IS PROPERLY SECURED WHEN SPRINKLER HEAD IS MOVED; OK TO SHEETROCK ONE SIDE THROUGHOUT |
| 11/28/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 11/28/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 11/28/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 11/28/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 11/28/2007 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
| 12/03/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE THROUGHOUT |
| 12/06/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK FOR CEILING TILES |
| 12/10/2007 | FIRE - FINAL | LTHOMAS | Approved | |
| 12/10/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 12/12/2007 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 12/13/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 12/14/2007 | BUILDING - FINAL | MHENSON | Approved | IVRS - Inspection :* |
| 12/14/2007 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1. FINISH SUPPORTING VDV AS PER 725.6, 800.24, 300.11 2. BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEED APPROVED EXTENDER RINGS 314.20 RECEIVED GENERATOR TEST REPORT |
| 12/14/2007 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/14/2007 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 12/17/2007 | PERMIT FINALED | BFLORES | Approved |