Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM04236
Permit Details
Status:
Expired
Type:
SINGLE FAMILY NEW
Address:
2456 E CAMINO MALCOTE
Address NEW:
2456 E CAMINO MALCOTE
Apply Date:
10/31/2007
Applicant:
D R HORTON HOMES *C
Description:
SFR:16-90-71 T07-M0062
Contractors:
- D R HORTON HOMES *C
Permit Reviews
Permit Number - T07CM04236
Permit Status: Expired
Permit Description: SFR:16-90-71 T07-M0062
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/31/2007 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 11/01/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM04236
Permit Status: Expired
Permit Description: SFR:16-90-71 T07-M0062
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/31/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07CM04236
Permite Description: SFR:16-90-71 T07-M0062
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PERMIT FINALED | N/A | Not Inspected | ||
| 02/22/2008 | ASSURANCE | N/A | Not ready for Inspection |
Completed Inspections
Permit Status: Expired
Permit Number: T07CM04236
Permit Description: SFR:16-90-71 T07-M0062
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2007 | PLUMBING - ROUGH, SOIL | EDURAZO | Approved | IVRS - Inspection :* |
| 12/13/2007 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* PROVIDE COPY OF SOILS REPORT |
| 12/13/2007 | ELECTRIC - UFER | EDURAZO | Approved | IVRS - Inspection :* REBAR STUB FOR FUTURE GROUND |
| 12/13/2007 | STEM WALL/RETAINING WALL | EDURAZO | Approved | IVRS - Inspection :* |
| 12/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* |
| 12/20/2007 | ROOF NAILING | EDURAZO | Approved | IVRS - Inspection :* |
| 12/20/2007 | EXT METAL CLIPS/EXT SHEATHING | EDURAZO | Approved | IVRS - Inspection :* |
| 12/28/2007 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 12/28/2007 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection :* |
| 12/28/2007 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* |
| 12/31/2007 | FRAMING | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL GUSSET PLATES TRUSS ABOVE LEFT 2) GROUND LIGHT BOX DINING AREA 3) OK TO INSULATE |
| 12/31/2007 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection :* |
| 12/31/2007 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 01/07/2008 | SHEET ROCK NAILING | EDURAZO | Approved | IVRS - Inspection :* |
| 01/25/2008 | PLUMBING - SEWER HCS CONNECT | EDURAZO | Approved | IVRS - Inspection :* |
| 04/28/2008 | PLUMBING - YARD WTR LINE/TEST | EDURAZO | Approved | |
| 04/28/2008 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 04/28/2008 | PLUMBING - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 04/28/2008 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 04/28/2008 | BUILDING - FINAL | EDURAZO | Approved | IVRS - Inspection :$ |
| 04/29/2008 | ELECTRIC - CABLE DROP | EDURAZO | Approved | |
| 04/29/2008 | ELECTRIC - TEMPORARY SERVICE | EDURAZO | Approved |