Permit: T07CM04236

Parcel: 14026002D

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T07CM04236

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/02/2008 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
12/31/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/28/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. FINISH ELECT., BANG PLATES THROUGHOUT
2. NAIL OSB SHEAR TO STUDS AT H.D'S
3. FLR. TRUSS CUT FOR TOILET FIX TOP CORD
4. INSTALL TWO HTT22'S AT GARAGE TO HOUSE NAIL DBL STUDS TO OSB
5. A02 C TRUSS MISSING GUSSET PLATE BOTH SIDES AT JOINT
6. GAS/H2O AIR TEST OK
7. 2ND FLR. SHEAR WALLS (11) 2 1/2" 16d (10) 3" (1) 12"
(sole plate)
8. ELECT. BOXES AT STUCCO LATHE NEED TO BE CAULKED
9. PLAN DOESN'T EXPLAIN WHEN CABLES ARE TO BE PULLED.