Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address NEW:
7574 E AUTUMN LEAF DR
Apply Date:
10/26/2007
Applicant:
MONTEREY HOMES CONSTRUCTION INC *C
Description:
SFR:TD# 16-66-76T06-M0118
Contractors:
  • MERITAGE HOMES CONSTRUCTION INC

Permit Reviews

Permit Number - T07CM04202
Permit Status: Final
Permit Description: SFR:TD# 16-66-76T06-M0118
Start Date Submittal Complete Date Status  
10/26/2007 RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU 10/29/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM04202
Permit Status: Final
Permit Description: SFR:TD# 16-66-76T06-M0118
Total Outstanding Activity Conditions - 1
Date Name
10/26/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T07CM04202
Permit Description: SFR:TD# 16-66-76T06-M0118
Total Completed Inspections - 26
Date Description Inspector Results Comments
11/30/2007 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection :*
11/30/2007 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection :*
11/30/2007 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
12/06/2007 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection :*
12/06/2007 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
12/06/2007 STEM WALL/RETAINING WALL RFREIDIN Approved IVRS - Inspection :*
12/06/2007 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
12/28/2007 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. CHECK WITH TRUSS CO. C-1 TRUSS TOP CHORD NOTCHED FOR OUTRIGGER DOESN'T HAVE CONTINUOUS BEARING
2. OSB TURNED WRONG WAY NEEDS TOO BE BLOCKED, ON ROOF DECK MARKED IN BLACK
3. AT ROOM PORCH DECK TO PARAPET BLK EDGE OF ROOF DECK AT PARAPET WALL
4. DAMAGED OSB AT RIDGE
5. NAIL OFF SHEATHING AT ENTRY ABOVE FRONT DOOR INSIDE OSB TO TRUSSES AND AT WEST SIDE OF TOWER

7/SD3 TIE SHEAR TO TRUSS GARAGE/FRONT BEDROOM
12/28/2007 ROOF NAILING RFREIDIN Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/08/2008 ELECTRIC - TEMPORARY SERVICE RFREIDIN Approved IVRS - Inspection :*
01/08/2008 ELECTRIC - CABLE DROP RFREIDIN Approved IVRS - Inspection :*
01/09/2008 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. FREIDINGER
01/28/2008 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
01/28/2008 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection :*
01/28/2008 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
01/28/2008 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
01/28/2008 U VALUE FOR WINDOW RFREIDIN Approved IVRS - Inspection :*
01/28/2008 STUCCO MESH RFREIDIN Approved IVRS - Inspection :*
02/04/2008 FRAMING WNORTH Approved IVRS - Inspection :*
02/07/2008 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection :*
04/03/2008 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection :*
04/03/2008 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection :*
04/03/2008 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection :*
04/10/2008 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :*
12/29/2008 PERMIT FINALED BGRANT Approved
12/29/2008 ASSURANCE BGRANT Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW