Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM04202
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/02/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) NOTE: TRUSS PROBLEM MASTER |
|
| 12/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CHECK WITH TRUSS CO. C-1 TRUSS TOP CHORD NOTCHED FOR OUTRIGGER DOESN'T HAVE CONTINUOUS BEARING 2. OSB TURNED WRONG WAY NEEDS TOO BE BLOCKED, ON ROOF DECK MARKED IN BLACK 3. AT ROOM PORCH DECK TO PARAPET BLK EDGE OF ROOF DECK AT PARAPET WALL 4. DAMAGED OSB AT RIDGE 5. NAIL OFF SHEATHING AT ENTRY ABOVE FRONT DOOR INSIDE OSB TO TRUSSES AND AT WEST SIDE OF TOWER 7/SD3 TIE SHEAR TO TRUSS GARAGE/FRONT BEDROOM |