Permit: T07CM02941
Permit Details
Apply Date:
07/12/2007
Applicant:
METRO PERMIT EXPRESS
Description:
NEW DENTAL OFFICE BLDG
Contractors:
- VENTURE WEST INC *C
Permit Reviews
Permit Number - T07CM02941
Permit Status: C of o
Permit Description: NEW DENTAL OFFICE BLDG
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/12/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 07/13/2007 | COMPLETED |
07/13/2007 | 3RD PARTY REVIEW-COMMERCIAL | 09/04/2007 | COMPLETED |
09/04/2007 | POST 3RD PARTY REVIEW | 09/11/2007 | COMPLETED |
10/10/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 10/17/2007 | COMPLETED |
10/16/2007 | POST 3RD PARTY REVIEW | 10/17/2007 | COMPLETED |
11/08/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 11/13/2007 | COMPLETED |
12/10/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 12/18/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM02941
Permit Status: C of o
Permit Description: NEW DENTAL OFFICE BLDG
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/12/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM02941
Permit Description: NEW DENTAL OFFICE BLDG
Total Completed Inspections - 39
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/01/2007 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
10/01/2007 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
10/10/2007 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* OK TO POUR |
10/10/2007 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* CONTINUOUS FOOTINGS & COLUMN FOOTINGS OK TO POUR |
10/24/2007 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* OK 4 - 3/4" PVC & RIGID 90 DEG'S |
11/08/2007 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* CLIPS & SHEATHING (STRAPS) AS PER PLANS OK TO COVER |
11/21/2007 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* SW TOWER COMPLETE - OK TO DRY IN |
12/19/2007 | ELECTRIC - OUTDOOR LIGHTING | RHOLLAND | Approved | IVRS - Inspection :* OK 5 SOFFIT CANS |
12/20/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* OK FOR SHEETROCK SUSPENDED ROUGH DUCT & SUPPLY & EXHAUST IN RESTROOMS. CONDENSATE OK. |
12/20/2007 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* OK TO STUCCO EXTERIOR WALLS |
12/20/2007 | PLUMBING - SEWER HCS CONNECT | BBENEDON | Approved | IVRS - Inspection :* |
12/20/2007 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* |
12/20/2007 | MECHANICAL - PROGRESS | IVR USER | Approved | IVRS - RI canceled |
12/20/2007 | MECHANICAL - ABOVE CEILING | IVR USER | Approved | IVRS - RI canceled |
12/20/2007 | PLUMBING - ABOVE CEILING | IVR USER | Approved | IVRS - RI canceled |
12/20/2007 | ELECTRIC - ABOVE CEILING | IVR USER | Approved | IVRS - RI canceled |
12/21/2007 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* 1) CLOSET FLANGE OK |
12/21/2007 | MECHANICAL - INTERMEDIATE | IVR USER | Approved | IVRS - RI canceled |
12/28/2007 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* CANCELLED |
01/07/2008 | FRAMING | JBURGE | Approved | IVRS - Inspection :* OK TO SHEETROCK THROUGHOUT PENDING ELECTRIC & PLUMBING INTERMEDIATES |
01/16/2008 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE THROUGHOUT |
02/07/2008 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* OK TO SET TILES |
02/27/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | TMPP CLEARED PER R. HOLLANDER |
03/19/2008 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
03/19/2008 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* |
03/19/2008 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
03/19/2008 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
03/19/2008 | FIRE - FINAL | DRAMIREZ | Approved | APPROVED 3/19/08. |
03/19/2008 | NPPO - FINAL | ACONNOR | Approved | |
03/19/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
03/20/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
03/20/2008 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* PENDING ELECTRIC FINAL |
03/21/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* * EQUIPMENT THAT WAS NOT LISTED HAS BEEN REMOVED IF REINSTALLED PROPER LISTING & LABELING WILL BE REQUIRED CUSTOMER HAS BEEN MADE AWARE |
03/21/2008 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
03/21/2008 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection :* |
03/21/2008 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :* |
03/21/2008 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection :* |
03/21/2008 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :* |
03/21/2008 | ENGINEERING - FINAL | JBRUCKME | Approved | APPROVED ON CONDITION, NO OTHER C OF O'S WILL BE GRANTED UNTIL FINAL GRADING INSPECTION APPROVAL. Tanque Verde Place T04BU02272 Preliminary Grading Punch list March 20, 2008 The following item must be completed prior to final approval of the grading permit and Certificate of Occupancy for lots 9, 10, 32-37 AND ALL LOTS OUTSTANDING. 1. Construct all sidewalks as shown on the approved plans. 2. Construct all sidewalk scuppers per approved plans. 3. Construct drainage swale behind lots 44-47 per plan. 4. Clean drainage pipe behind lots 28, 29. 5. Grout rip rap outfalls per approved plan. 6. Install concrete gutters or revise plan. 7. Revise the grading plan per red line drawings. 8. Install stop signs per plan. 9. Expose all storm drain manhole covers. 10. Submit an Engineers certification for lots 1-14. 11. Repair/ replace all broken or damaged sidewalk and ramps that have two or more through cracks per panel. 12. Trim basin and swale slopes to match plan grades and cross section. 13. Show slope grades at southeast side of lot 57. Slopes steeper then 2:1 require grouted rip rap. 14. Covered parking canopies extend 1 foot into the required PAAL. Have Engineer address with Zoning. 15. Provide detail for both type I and II bicycle parking, and provide lighting as noted on approved plan. 16. Show location of all handrails on as-built plan. 17. Provide inlet and outlet flow line elevation for all underground pipe. 18. Provide detail for drainage swale along west edge of property. Sidewalk/porch extends into area for swale. 19. Insure a minimum of 4 ft sidewalk clearance at building pop outs, electrical panels, etc. 20. Insure a minimum 24 ft PAAL at lot 2. 21. Insure water does not pond at all curb ramps. 22. Provide type B post barricades in trash enclosures per approved plan. Please address above items and call for reinspection. |