Permit: T07CM02727
Permit Details
Apply Date:
06/26/2007
Applicant:
FAST PERMITS
Description:
ADDITION:LAUNDRY ROOM
Permit Reviews
Permit Number - T07CM02727
Permit Status: Final
Permit Description: ADDITION:LAUNDRY ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/26/2007 | PLANS OK TO SUBMIT - RES | 06/26/2007 | COMPLETED |
| 06/26/2007 | 3RD PARTY REVIEW-RESIDENTIAL | 08/10/2007 | COMPLETED |
| 06/26/2007 | POST 3RD PARTY REVIEW | 08/11/2007 | COMPLETED |
| 08/11/2007 | RESUBMITTAL | 08/15/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM02727
Permit Status: Final
Permit Description: ADDITION:LAUNDRY ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/26/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM02727
Permit Description: ADDITION:LAUNDRY ROOM
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/05/2007 | ELECTRIC - SERVICE UPGRADE | JRIVA | Approved | IVRS - Inspection : Install 2 ground rods 6 feet apart with a continuous grounding electrode connection Provide proof of an approved ufer ground or install tw0 8 ft ground rods 6 ft apart connected to the service panel with a continous #4 conductor Splicing ground wire with split bolts not allowed Put address on panel |
| 09/05/2007 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection :* |
| 09/05/2007 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection :* |
| 09/13/2007 | PLUMBING - PRE SLAB | DWALKER | Approved | IVRS - Inspection :* |
| 09/13/2007 | BUILDING PRE-SLAB | DWALKER | Approved | IVRS - Inspection :* |
| 11/06/2007 | FRAMING | DWALKER | Approved | IVRS - Inspection :* |
| 11/06/2007 | MECHANICAL - INTERMEDIATE | DWALKER | Approved | IVRS - Inspection :* |
| 11/06/2007 | PLUMBING - INTERMEDIATE | DWALKER | Approved | IVRS - Inspection :* |
| 11/06/2007 | ELECTRIC - INTERMEDIATE | DWALKER | Approved | IVRS - Inspection :* |
| 11/06/2007 | SHEET ROCK NAILING | DWALKER | Approved | IVRS - Inspection :* |
| 11/15/2007 | STUCCO MESH | DWALKER | Approved | IVRS - Inspection :* |
| 01/25/2008 | MECHANICAL - FINAL | DWALKER | Approved | |
| 01/25/2008 | PLUMBING - FINAL | DWALKER | Approved | |
| 01/25/2008 | ELECTRIC - FINAL | DWALKER | Approved | |
| 01/25/2008 | BUILDING - FINAL | DWALKER | Approved | IVRS - Inspection :* |
| 01/28/2008 | PERMIT FINALED | JWEATHER | Approved |