Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07CM02159
Permit Details
Apply Date:
05/24/2007
Applicant:
GAINOUS LOYD JR
Description:
NEW SFR R1:Enclose carport to garage, Delete porch areas, Truss review 11/20/07
Permit Reviews
Permit Number - T07CM02159
Permit Status: C of o
Permit Description: NEW SFR
R1:Enclose carport to garage, Delete porch areas, Truss review 11/20/07
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/24/2007 | PLANS OK TO SUBMIT - RES | 05/25/2007 | COMPLETED |
05/25/2007 | RESIDENTIAL BLDG/WWM | 06/25/2007 | COMPLETED |
06/27/2007 | RESUBMITTAL | 07/10/2007 | COMPLETED |
11/20/2007 | REVISION - - 1ST | 11/20/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM02159
Permit Status: C of o
Permit Description: NEW SFR
R1:Enclose carport to garage, Delete porch areas, Truss review 11/20/07
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/24/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM02159
Permit Description: NEW SFR
R1:Enclose carport to garage, Delete porch areas, Truss review 11/20/07
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/06/2007 | PLUMBING - ROUGH, SOIL | DWALKER | Approved | IVRS - Inspection :* |
08/08/2007 | PLUMBING - YARD WTR LINE/TEST | DWALKER | Approved | IVRS - Inspection :* 1) NO METER 2) CITY REQUIRED GREEN TRACER WIRE ON SEWER LINE FROM HCS TO DBL CLEANOUTS AT BLDG |
08/09/2007 | PLUMBING - SEWER HCS CONNECT | EDURAZO | Approved | IVRS - Inspection :* |
08/13/2007 | BUILDING PRE-SLAB | EDURAZO | Approved | |
08/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | |
08/13/2007 | ELECTRIC - UFER | EDURAZO | Approved | IVRS - Inspection :* |
08/13/2007 | STEM WALL/RETAINING WALL | EDURAZO | Approved | IVRS - Inspection :* |
11/25/2007 | ROOF NAILING | EDURAZO | Approved | IVRS - Inspection :* |
11/25/2007 | EXT METAL CLIPS/EXT SHEATHING | EDURAZO | Approved | IVRS - Inspection :* |
12/27/2007 | STUCCO MESH | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) CAULK CLEANOUTS AND PIPES N.W. CORNER 2) FURR OUT DRYER VENT FURNACE ROOM 3) STUD MISSING FRONT HALL 4) WIRE TO ISLAND ? 5) INSTALL VACUUM BREAKERS ON HOSE BIBS 6) NAIL STOP TOP PLATE MASTER TOILET 7) NO DWV TEST. SUPPLY OK 8) BLOCK RETURN AIR BOOTS 9) EXTEND RANGE HOOD DUCT THRU CEILING |
12/27/2007 | FRAMING | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/27/2007 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/27/2007 | PLUMBING - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
12/27/2007 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
02/01/2008 | SHEET ROCK NAILING | WLAHR | Approved | IVRS - Inspection :* |
03/17/2008 | ELECTRIC - PROGRESS | CRUIZ | Approved | IVRS - Inspection :* 1) INSPECTED AND OK'D CONDUIT IN KITCHEN FLOOR FOR ISLAND |
03/17/2008 | ELECTRIC - TEMPORARY SERVICE | CRUIZ | Approved | IVRS - Inspection :* |
03/17/2008 | ELECTRIC - CABLE DROP | CRUIZ | Approved | IVRS - Inspection :* |
03/18/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER C. RUIZ |
06/24/2009 | PERMIT FINALED | JWEATHER | Approved | |
06/24/2009 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
06/24/2009 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
06/24/2009 | BUILDING - FINAL | EDURAZO | Approved | IVRS - Inspection :* |