Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2009 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/19/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS TO REAR YARD 2) COMPLY WITH #4, 2, 5, 6 & 8 OF PREVIOUS INSPECTION |
|
| 06/18/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS ON FRONT WALL 2) INSTALL RANGE ANTI-TIP 3) GARAGE/HOUSE DOOR SHALL BE SELF CLOSING 4) PROTECT WIRE AT RANCH HOOD AND USE APPROVED CORD 5) BONDING JUMPER MISSING AT DUCT BY A/C WITH FLEX BOOT 6) GROUND WATER HEATER TO BE VISIBLE ON TOP 7) VACUUM BREAKER MISSING AT WEST HOSE BIB 8) AL LIGHT NOT UNDER PORCH SHALL BE SHIELDED 9) PROVIDE APPROVED DRAWINGS SHOWING DELETION OF OR PART OF PORCHES |