Permit: T07CM01364
Permit Details
Apply Date:
04/02/2007
Applicant:
CRYSTAL HOMES AND DEVELOPMENT L L C
Description:
DUPLEX:TD16-56-10 T05-M0365
Contractors:
- CRYSTAL HOMES AND DEVELOPMENT L L C
Permit Reviews
Permit Number - T07CM01364
Permit Status: Final
Permit Description: DUPLEX:TD16-56-10 T05-M0365
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/02/2007 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 04/03/2007 | COMPLETED |
| 06/20/2007 | REVISION - - 1ST | 06/20/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01364
Permit Status: Final
Permit Description: DUPLEX:TD16-56-10 T05-M0365
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/02/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM01364
Permit Description: DUPLEX:TD16-56-10 T05-M0365
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2007 | ELECTRIC - UFER | LHANLY | Approved | IVRS - Inspection :* |
| 04/23/2007 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection :* |
| 04/30/2007 | STEM WALL/RETAINING WALL | AALEGRIA | Approved | IVRS - Inspection :* STEM WALL 8X8X16 WITH 1 #4 HORIZ. ON BOND BEAM CONT. AND #4 @ 48" O.C FROM FOUNDATION |
| 05/04/2007 | PLUMBING - ROUGH, SOIL | RLEDONNE | Approved | IVRS - Inspection :* |
| 05/07/2007 | BUILDING PRE-SLAB | AALEGRIA | Approved | IVRS - Inspection :* |
| 05/11/2007 | PLUMBING - SEWER HCS CONNECT | RLEDONNE | Approved | IVRS - Inspection :* |
| 05/16/2007 | REINFORCED MASONRY PRE-GROUT | AALEGRIA | Approved | IVRS - Inspection :* @ TOPOUT |
| 06/20/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* PROVIDE SCREENS IN EXHAUST FAN T-TOPS OK FOR SHEETROCK |
| 06/28/2007 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 06/28/2007 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* |
| 06/28/2007 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* |
| 06/28/2007 | U VALUE FOR WINDOW | AALEGRIA | Approved | IVRS - Inspection :* |
| 06/28/2007 | EXT METAL CLIPS/EXT SHEATHING | AALEGRIA | Approved | IVRS - Inspection :* |
| 06/28/2007 | ROOF NAILING | AALEGRIA | Approved | IVRS - Inspection :* |
| 06/28/2007 | FRAMING | AALEGRIA | Approved | IVRS - Inspection :* |
| 07/06/2007 | SHEET ROCK NAILING | AALEGRIA | Approved | IVRS - Inspection :* |
| 10/03/2007 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | |
| 10/03/2007 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 10/03/2007 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | |
| 10/03/2007 | ELECTRIC - CABLE DROP | DSANTACR | Approved | |
| 10/03/2007 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | |
| 10/04/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR #1 & #2 PER D. SANTACRUZ-2ND TIME SENT TO TEP FOR UNIT #2 |
| 10/08/2007 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
| 10/09/2007 | PERMIT FINALED | BFLORES | Approved | |
| 10/09/2007 | STUCCO MESH | LHANLY | Approved | |
| 10/09/2007 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 10/09/2007 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |