Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/04/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NO ACCESS @ 8:10 COMPLETE ALL WORK, PROVIDE ACCESS FAILURE TO DO SO SHALL RESULT IN REFEE |
|
| 10/03/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. REMOVE TAPE AT DRAFT SPACE OF SINGLE TO DOUBLE WALL VENT CONNECTION ON WATER HEATER & PROVIDE 3-GALV SCREWS AT ALL VENT JOINTS 2. PROVIDE WATER HAMMER ARRESTORS FOR WASHER BOX WATER SUPPLIES 3. PROVIDE COCK HOLE COVERS AT KITCHEN SINK 4. VENT FROM WATER HEATER TO BE 3' ABOVE COMBUSTION AIR INTAKE 5. EXPOSE PIPING FOR 5/4/07 INSPECTION |
|
| 10/02/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SHALL HAVE ACCESS TO BOTH UNITS (1) LOCKED PROVIDE PROOF OF 03040 INSPECTION APPROVAL OR EXPOSE PER NOTE FROM 5/4/07 INSPECTION - PROVIDE FINAL GAS TEST - LIST NOT COMPLETE |