Permit: T07CM01364

Parcel: 120085640

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/08/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
10/04/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ACCESS @ 8:10
COMPLETE ALL WORK, PROVIDE ACCESS FAILURE TO DO SO SHALL RESULT IN REFEE
10/03/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. REMOVE TAPE AT DRAFT SPACE OF SINGLE TO DOUBLE WALL VENT CONNECTION ON WATER HEATER & PROVIDE 3-GALV SCREWS AT ALL VENT JOINTS
2. PROVIDE WATER HAMMER ARRESTORS FOR WASHER BOX WATER SUPPLIES
3. PROVIDE COCK HOLE COVERS AT KITCHEN SINK
4. VENT FROM WATER HEATER TO BE 3' ABOVE COMBUSTION AIR INTAKE
5. EXPOSE PIPING FOR 5/4/07 INSPECTION
10/02/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SHALL HAVE ACCESS TO BOTH UNITS (1) LOCKED
PROVIDE PROOF OF 03040 INSPECTION APPROVAL OR EXPOSE PER NOTE FROM 5/4/07 INSPECTION - PROVIDE FINAL GAS TEST - LIST NOT COMPLETE