Permit: T07CM01302
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
310 S WILLIAMS BL #340
Address NEW:
310 S WILLIAMS BL #340
Apply Date:
03/30/2007
Applicant:
N/A
Description:
TI: OFFICE
Architects:
- SWAN WAYNE E
Contractors:
- SCOGGIN CONTRACTING INC
Permit Reviews
Permit Number - T07CM01302
Permit Status: C of o
Permit Description: TI: OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/30/2007 | COMMERCIAL TI | 05/21/2007 | COMPLETED |
| 05/21/2007 | OTHER | 05/22/2007 | COMPLETED |
| 05/25/2007 | OTHER | 10/11/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01302
Permit Status: C of o
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/30/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T07CM01302
Permit Description: TI: OFFICE
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 11/07/2007 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 11/07/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* EXISTING APPEARS TO CONFORM TO CODE |
| 11/07/2007 | FRAMING | GDABBS | Approved | IVRS - Inspection :* EXISTING FRAMING APPEARS TO CONFORM TO CODE |
| 11/07/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 11/07/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 11/07/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 11/07/2007 | FIRE - FINAL | LTHOMAS | Approved | |
| 12/10/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* SECURE DISHWASHER DRAIN HOSE WITH HIGH LOOP 'MAXIMUM 2" BELOW TOP OF COUNTER WITH 2-HOLE STRAP |
| 12/11/2007 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. CIRCUIT FOR INSTANT HOT NOT SIZED PROPERLY 120V 3KW UNIT REQUIRES 30 AMP CIRCUIT CANNOT BE CORD & PLUG CONNECTED NEEDS DISCONNECTING MEANS 2. OK CEILINGS |
| 12/11/2007 | ENGINEERING - FINAL | NKALAHAR | Approved | |
| 02/29/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
| 03/04/2008 | PERMIT FINALED | BFLORES | Approved |