Permit: T07CM01271
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
971 W WEDWICK ST
Address NEW:
971 W WEDWICK ST
Apply Date:
03/29/2007
Applicant:
LUIS MARTINEZ
Description:
ENCLOSE:STORAGE ROOM TO BEDROOM T07VL00009
Permit Reviews
Permit Number - T07CM01271
Permit Status: Expired
Permit Description: ENCLOSE:STORAGE ROOM TO BEDROOM T07VL00009
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/29/2007 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 08/30/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM01271
Permit Status: Expired
Permit Description: ENCLOSE:STORAGE ROOM TO BEDROOM T07VL00009
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/29/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07CM01271
Permite Description: ENCLOSE:STORAGE ROOM TO BEDROOM T07VL00009
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/24/2007 | SHEET ROCK NAILING | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 09/24/2007 | BUILDING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 11/13/2007 | FRAMING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK REGISTER BOOT 3-SIDES 2) PROVIDE CONTINOUS TIE DOWN FROM BOTTOM PLATES TO TOP RAFTERS-MISSING CLIPS 3) PROVIDE 1" CLEARANCE B-VENT FROM PLYWOOD 4) ALL PLATES TOUCHING CONCRETE MUST BE TREATED 5) NAIL PROTECT ROMEX UNDER 1 1/4" CLEARANCE END OF STUD 6) EXTEND TPR VALVE TO EXTERIOR |
| 11/13/2007 | ELECTRIC - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 11/13/2007 | MECHANICAL - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/30/2007 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OWNER NEEDS TO CHANGE W/HEATER TO ELECTRIC. PLAN SHOWS ELECTRIC WATER HEATER TO BE USED. ITEMS #3 & #6 FROM PREVIOUS INSPECTION NOT MET, BECAUSE OWNER SAYS THEY WILL CHANGE OUT W/HEATER TO ELECTRIC 2) OK TO SHEET ROCK EXT WALLS EXCEPT FOR MECHANICAL ROOM |
Completed Inspections
Permit Status: Expired
Permit Number: T07CM01271
Permit Description: ENCLOSE:STORAGE ROOM TO BEDROOM T07VL00009
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2007 | ELECTRIC - INTERMEDIATE | CRUIZ | Approved | IVRS - Inspection :* |
| 11/02/2007 | U VALUE FOR WINDOW | CRUIZ | Approved | IVRS - Inspection :* |