Inspection History Details
Inspection Status: Denied
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/11/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXCEPT MECH ROOM |
|
| 11/13/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK REGISTER BOOT 3-SIDES 2) PROVIDE CONTINOUS TIE DOWN FROM BOTTOM PLATES TO TOP RAFTERS-MISSING CLIPS 3) PROVIDE 1" CLEARANCE B-VENT FROM PLYWOOD 4) ALL PLATES TOUCHING CONCRETE MUST BE TREATED 5) NAIL PROTECT ROMEX UNDER 1 1/4" CLEARANCE END OF STUD 6) EXTEND TPR VALVE TO EXTERIOR |
|
| 11/02/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED 2 X BLOCK BETWEEN RAFTER (BIND BOARD ? ) 2) BLOCK DUCT 3 SIDES 3) NEED TO COMPLETE FURRED OUT WALL 4) NEED TO RELOCATE HIGH PRESSURE RELIEF VALVE |
|
| 09/24/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) REMOVE ALL SHEETROCK 2) RECALL INTERMEDIATE WHEN READY 3) WORK NOT COMPLETE 4) REMOVE ALL ITEMS FROM STORAGE |