Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
625 W PRESIDENT ST
Apply Date:
03/27/2007
Applicant:
JAMES BROOKS
Description:
REPL HVAC, WATER HEATER, GAS LINE AND ELEC UPGRADE 200AMPS (T05EL01746)
Contractors:
  • LA CAUSA CONSTRUCTION L L C

Permit Reviews

Permit Number - T07CM01218
Permit Status: Expired
Permit Description: REPL HVAC, WATER HEATER, GAS LINE AND ELEC UPGRADE 200AMPS (T05EL01746)
Start Date Submittal Complete Date Status  
03/27/2007 OTHER 03/27/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM01218
Permit Status: Expired
Permit Description: REPL HVAC, WATER HEATER, GAS LINE AND ELEC UPGRADE 200AMPS (T05EL01746)
Total Outstanding Activity Conditions - 1
Date Name
03/27/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07CM01218
Permite Description: REPL HVAC, WATER HEATER, GAS LINE AND ELEC UPGRADE 200AMPS (T05EL01746)
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
01/29/2008 PLUMBING - FINAL N/A Cancelled CANCELLED PER CHERIL HOWARD OF LA CAUSA CONST. #631-3614
01/29/2008 MECHANICAL - FINAL N/A Cancelled CANCELLED PER CHERIL HOWARD OF LA CAUSA CONST. #631-3614
11/09/2007 ELECTRIC - SERVICE UPGRADE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. USE APPROVED J-BOX FOR SPLICES AT OLD SUB-PANEL
2. BOND WATER & GAS PIPING
3. SUPPORT RISER WITHIN 3" OF SERVICE PANEL,
USE 1/4" MIN. BOLTS
4. INSTALL BOND BUSHINGS AT CONCENTRIC WITH REDUCING WASHERS.
5. FLEX CONNECTOR NOT PROPER FITTING AT GFI RECEPT ALSO SUPPORT BOX
- SERVICE IS RE-ENERGIZED PRIOR TO INSP. APPROVAL
6. INSTALL A RISER BRACE ON ROOF AS REQUIRED
PER 230 NEC
11/13/2007 PLUMBING - GAS PRESSURE TEST N/A Not ready for Inspection IVRS - Inspection :*
BOND GAS LINE
PROVIDE REDUCER 3/4" TO 1/2" AT ROOF
FURNACE-GAS SHUT OFF SHALL BE IN FRONT OF FLEX
GAS TEST OK
INSTALL WATER HEATER PRIOR TO FINAL