Permit: T07CM00815
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
4734 S GOLDENROD PL
Address NEW:
4734 S GOLDENROD PL
Apply Date:
03/01/2007
Applicant:
KASMAR NATALIE A
Description:
REPLACE EVAP COOLER WITH AC /HEAT PACKAGE UNIT: T06DV02564 ATTACH:UPGRADE ELECTRIC
Permit Reviews
Permit Number - T07CM00815
Permit Status: Final
Permit Description: REPLACE EVAP COOLER WITH AC /HEAT PACKAGE UNIT: T06DV02564 ATTACH:UPGRADE ELECTRIC
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/01/2007 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 03/05/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM00815
Permit Status: Final
Permit Description: REPLACE EVAP COOLER WITH AC /HEAT PACKAGE UNIT: T06DV02564 ATTACH:UPGRADE ELECTRIC
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/01/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07CM00815
Permit Description: REPLACE EVAP COOLER WITH AC /HEAT PACKAGE UNIT: T06DV02564 ATTACH:UPGRADE ELECTRIC
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2007 | ELECTRIC - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) CONDENSATE DRAIN MUST BE MINIMUM 3/4 AND ENTER SEPERATE DRAIN 2) SUPPORT DRAIN ON BLOCKS MINIMUM EVERY 4' 3) PAINT PVC WITH LATEX PAINT 4) INSTALL DRIP LEG ON GAS SUPPLY 5) SECURE FLEX FOR ELECTRIC WITHIN 12" OF EVERY CONNECTION 6) FLEX AT DISCONNECT IS PULLED LOOSE FROM CONNECTOR 7) OBTAIN PERMIT FOR ELECTRIC SERVICE UPGRADE |
| 08/29/2007 | MECHANICAL - FINAL | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/29/2007 | ELECTRIC - FINAL | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/29/2007 | MECHANICAL - INTERMEDIATE | WNORTH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/06/2008 | ELECTRIC - SERVICE UPGRADE | RFREIDIN | Approved | IVRS - Inspection :* |
| 08/07/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. FREIDINGER |
| 02/04/2009 | PERMIT FINALED | BFLORES | Approved |