Start Date Submittal Complete Date Status  
03/01/2007 RESIDENTIAL BLDG/ZONING-WALKTHRU 03/05/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM00815
Permit Status: Final
Permit Description: REPLACE EVAP COOLER WITH AC /HEAT PACKAGE UNIT: T06DV02564 ATTACH:UPGRADE ELECTRIC
Total Outstanding Activity Conditions - 1
Date Name
03/01/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T07CM00815
Permit Description: REPLACE EVAP COOLER WITH AC /HEAT PACKAGE UNIT: T06DV02564 ATTACH:UPGRADE ELECTRIC
Total Completed Inspections - 7
Date Description Inspector Results Comments
08/29/2007 ELECTRIC - INTERMEDIATE WNORTH Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) CONDENSATE DRAIN MUST BE MINIMUM 3/4 AND ENTER SEPERATE DRAIN
2) SUPPORT DRAIN ON BLOCKS MINIMUM EVERY 4'
3) PAINT PVC WITH LATEX PAINT
4) INSTALL DRIP LEG ON GAS SUPPLY
5) SECURE FLEX FOR ELECTRIC WITHIN 12" OF EVERY CONNECTION
6) FLEX AT DISCONNECT IS PULLED LOOSE FROM CONNECTOR
7) OBTAIN PERMIT FOR ELECTRIC SERVICE UPGRADE
08/29/2007 MECHANICAL - FINAL WNORTH Approved IVRS - Inspection :
See detailed listing on site.| 999*
08/29/2007 ELECTRIC - FINAL WNORTH Approved IVRS - Inspection :
See detailed listing on site.| 999*
08/29/2007 MECHANICAL - INTERMEDIATE WNORTH Approved IVRS - Inspection :
See detailed listing on site.| 999*
08/06/2008 ELECTRIC - SERVICE UPGRADE RFREIDIN Approved IVRS - Inspection :*
08/07/2008 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED PER R. FREIDINGER
02/04/2009 PERMIT FINALED BFLORES Approved

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW