Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
12/28/2006
Applicant:
ARIZONA PLUMBING SERVICES *C
Description:
REPLACE: WATER HEATER (APA)
Contractors:
  • ARIZONA PLUMBING SERVICES *C

Outstanding Activity Conditions

Permit Number - T06PL02420
Permit Status: Expired
Permit Description: REPLACE: WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
Date Name
12/28/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL02420
Permite Description: REPLACE: WATER HEATER (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
02/23/2007 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING.
2. TEMPERATURE & PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT TERMINATING AT 90 DEG. DOWN 6"-24" FROM FINISH GRADE.
3. PLEASE PROVIDE ACCESS INTO CEILING SPACE THRU LOUVER IN CARPORT ABOVE & RIGHT OF WATER HEATER TO VERIFY CORRECT UNIT VENT CONNECTIONS FOR WATER HEATER VENTING.