Date Description Inspector Results Comments
02/23/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING.
2. TEMPERATURE & PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT TERMINATING AT 90 DEG. DOWN 6"-24" FROM FINISH GRADE.
3. PLEASE PROVIDE ACCESS INTO CEILING SPACE THRU LOUVER IN CARPORT ABOVE & RIGHT OF WATER HEATER TO VERIFY CORRECT UNIT VENT CONNECTIONS FOR WATER HEATER VENTING.