Permit: T06PL02402
Permit Details
Apply Date:
12/26/2006
Applicant:
ARIZONA PLUMBING SERVICES *C
Description:
REPLACE: WATER HEATER (APA)
Contractors:
- ARIZONA PLUMBING SERVICES *C
Outstanding Activity Conditions
Permit Number - T06PL02402
Permit Status: Expired
Permit Description: REPLACE: WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/26/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T06PL02402
Permite Description: REPLACE: WATER HEATER (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2007 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* READ ALL NOTES & COMPLY 1. DRAFT HOOD TO BE CONNECTED PROPERLY 2. ALL VENT CONNECTIONS TO BE MADE UP CORRECTLY AND SECURED WITH SHEETMETAL SCREWS. 3. T&P DRAIN TO BE CUT OFF 1" ABOVE MINIMUM FROM TOP LIP OF DRAIN PAN - NOTIFIED OWNER OF DANGEROUS CONDITION FOR VENT NOT CONNECTED ASKED HER TO SHUT OFF WATER HEATER. TOLD HER HOW TO. FAILURE TO COMPLY SHALL RESULT IN REFEE. PETITION OF APPEAL #2006-240 ON SITE 4. REMOVE PAPER AT CEILING LEVEL FROM DOUBLE WALL VENT |