Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1941 E FAYETTE VISTA
Apply Date:
12/26/2006
Applicant:
FRANCISCO GONZALEZ
Description:
REPAIR:GAS LINE

Permit Reviews

Permit Number - T06PL02400
Permit Status: Expired
Permit Description: REPAIR:GAS LINE
Start Date Submittal Complete Date Status  
12/26/2006 PLUMBING 12/26/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06PL02400
Permit Status: Expired
Permit Description: REPAIR:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
12/26/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T06PL02400
Permite Description: REPAIR:GAS LINE
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
12/27/2006 PLUMBING - GAS PRESSURE TEST N/A Not ready for Inspection IVRS - Inspection :*
1. PROVIDE MINIMUM 10 PSI TEST ON ENTIRE GAS SYSTEM AT TIME OF REINSPECTION. EXPOSE PIPING AT RISER LOCATION, PRIME THEN 10 MIL TAPE FITTINGS, PIPE & TOOL MARKS T0 6" ABOVE FINISH GRADE.
2. PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES.
3. PROVIDE MINIMUM 100 SQ. INCHES 10"X10" UPPER & LOWER COMBUSTION AIR FOR WATER HEATER.
4. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT & TERMINATE AT 90 DEG. DOWN ON EXTERIOR 6"-24" FROM FINISH GRADE.
5. VENT FROM FURNACE SHALL BE DOUBLE WALL THRU ROOF, CONTINUE DOUBLE WALL TO APPROVED DOUBLE WALL VENT CAP & TERMINATE MINIMUM 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE.