Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T06PL02363
Permit Details
Apply Date:
12/20/2006
Applicant:
HOME BUILDERS L L C
Description:
REPLACE EXISTING GAS LINE
Contractors:
- HOME BUILDERS L L C
Permit Reviews
Permit Number - T06PL02363
Permit Status: Final
Permit Description: REPLACE EXISTING GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/20/2006 | PLUMBING | 12/20/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL02363
Permit Status: Final
Permit Description: REPLACE EXISTING GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/20/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06PL02363
Permit Description: REPLACE EXISTING GAS LINE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) 3/4" IS UNDERSIZED FOR FURNACE, WATER HEATER AND STOVE 2) 1/2" TO FURNACE IS UNDERSIZED 3) EXTEND 3/4" PIPING TO FURNACE SUPPLY FROM FULL SIZED 1" TEE 4) SUPPORT PIPING WITHOUT STRAIN 5) USE GALVANIZED 2 HOLE STRAPS NOT PLUMBERS TAPE 6) SECURE WATER HEATER VENT WITH SCREWS-NO TAPE AT DBL WALL 7) SEDIMENT TRAPS REQUIRED AT WATER HEATER AND FURNACE 8) HAVE AGA VALVES ON SITE |
| 12/28/2006 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
| 01/03/2007 | PERMIT FINALED | BFLORES | Approved |