Permit: T06PL02363

Parcel: 122091850


Addresses:

4158 E WAVERLY ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL02363

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/02/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
12/28/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 3/4" IS UNDERSIZED FOR FURNACE, WATER HEATER AND STOVE
2) 1/2" TO FURNACE IS UNDERSIZED
3) EXTEND 3/4" PIPING TO FURNACE SUPPLY FROM FULL SIZED 1" TEE
4) SUPPORT PIPING WITHOUT STRAIN
5) USE GALVANIZED 2 HOLE STRAPS NOT PLUMBERS TAPE
6) SECURE WATER HEATER VENT WITH SCREWS-NO TAPE AT DBL WALL
7) SEDIMENT TRAPS REQUIRED AT WATER HEATER AND FURNACE
8) HAVE AGA VALVES ON SITE