Permit: T06PL02169
Permit Details
Apply Date:
11/28/2006
Applicant:
BILL SISSON PLUMBING
Description:
GAS:NEW LINE
Contractors:
- BILL SISSON PLUMBING
Permit Reviews
Permit Number - T06PL02169
Permit Status: Final
Permit Description: GAS:NEW LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/28/2006 | PLUMBING | 11/28/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06PL02169
Permit Status: Final
Permit Description: GAS:NEW LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/28/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T06PL02169
Permit Description: GAS:NEW LINE
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2006 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* TEST IS OK SUPPORT VERTICAL PIPE AT WH AND FURNACE PROTECT BELOW GROUND PIPING W/PRIMER AND 10 MIL TAPE OK FOR GAS AFTER CORRECTING OK TO FINAL AFTER APPROVING FAV |
| 12/01/2006 | PLUMBING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
| 12/01/2006 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
| 12/04/2006 | PERMIT FINALED | BFLORES | Approved |